High-speed 10 MS/s 16-Bit isolation module (4 channels) – High noise immunity. Suitable for testing and longterm monitoring for power generators and multi-output power supplies. Provides dynamic analysis of multi-channel data recording applications. For use with the DL950 ScopeCorder.
Max. sampling rate: 10 MS/s
A/D conversion resolution: 16 bit
Number of channels: 4
Max. input voltage (DC + ACpeak): 600V / 200V
High-Speed 100 MS/s 12-Bit Isolation Module (2 channels)
IsoPRO technology enables 1kV isolated measurements in combination with 700929 or 701947 probe and is designed for inverter / IGBT related applications in mind. Using high speed optical fiber-based transmission, the module achieves high speed ADC clock and data isolation and provides the performance needed to develop high efficiency inverters, which employ high voltages, large currents, and ever increasing switching speeds.
Applicable to DL350, DL850 series, DL950 and SL1000.
High-Speed 10 MS/s 12-Bit non-isolation Module (2 ch)
Non-Isolation version of model 720250
Applicable to DL350, DL850 series, DL950 and SL1000.
Temperature/high-precision voltage Module (2 ch)
Thermocouple (K, E, J, T, L, U, N, R, S, B, W, iron-doped gold/chromel), high sensitivity range (1 mV), and low noise (±4 µVtyp)
Applicable to DL350, DL850 series, DL950 and SL1000.
Strain Module with Shunt Calibration, type DSUB (2 channels) to be used in combination with 701957 or 701958 DSUB bridge head.
Using the strain module and strain gauge the ScopeCorder can detect and display mechanical stress (strain). It works on the principle that the resistance value of a metal foil changes as it expands and contracts.
Applicable to DL350, DL850 series, DL950 and SL1000.
Use the SENT monitoring module to decode the SENT protocol signal and display information on physical quantities from SENT output sensors.
Applicable to DL850V & DL850EV, DL350 (/VE option), DL950 (/VCE option) ScopeCorder Vehicle Edition only.
Passive Probe, 1000V(DC+ACpeak) CAT II, 60MHz, 10:1, 10MΩ, 2.5m
Wide operating temperature range(-40 to 85°C)
For isolated BNC input modules for ScopeCoder series
The 720930 and 720931 passive clamp-on current probes allow current waveform readings directly via analog input modules on ScopeCorders including the DL350 and DL850 using isolated BNC connections.
The 720931 passive clamp-on current probe anables current waveform readings directly via analog input modules on ScopeCorders including the DL350 and DL850 using isolated BNC connections.
8-bit, non-isolated, response speed: 1µs, threshold level approx 1.4V
Two measurement leads (B9879PX and B9879KX) included.
8-bit, non-isolated, response speed: 3µs or less, treshold level approx 1.4V
702911: 1 meter cable, 702912: 3 meter cable
For the DC power supply model (/DC). Cigarette lighter plug type.
T-adapter for BNC connectors. Use for circuits having voltage levels no greater than 42 V.
Safety-terminal-binding-post adapter. Use for circuits having voltage levels no greater than 42 V.
For conversion between BNC and female banana plug
Applicable for DL750/DL750P, SL1000 & SL1400.
2 pieces (red and black) in 1 set
length: 1.00 m
Used in combination with the 701959, 758921, 758922, or 758929
Rating: 1000 V CAT III/19 A
Set contains one black and one red clip
1000 Vrms-CAT II
2 pieces (red and black) in 1 set
Connected to the 758933, 758917, or 701901
Length: 0.3m
Applicable for DL750/DL750P, SL1000, SL1400
1000 Vrms CAT III, 1 set each of red and black
Equivalent to B9852MM (Color Black)
Equivalent to B9852NM (Color Red)
Connected to the 700929, 701947
Maximum input voltage: 1,000V (DC + ACpeak)
Length: 0.26m/0.3m/0.4m
Applicable for DL750/DL750P, SL1000, SL1400
Set contains one black and one red clip.
1000 Vrms-CAT II.
Rated at 300 V. Attaches to the 758917 test leads. Sold in pairs.
Screw-fastened adapters. Two adapters in a set. 1.5 mm Allen Wrench.
BNC-BNC 2m. For connection to simultaneously measurement with 2 units, or for input external trigger signal.
A subassembly of 1.2 m long test leads with alligator-clip adapters.
Use only for circuits having voltage levels no greater than 42 V.
Applicable for SL1000 & SL1400.
This is an AC Adaptor for the Portable DL350 ScopeCorder available for use in multiple global regions (North America adaptor pictured).
Frequency bandwidth: DC to 120 MHz
Maximum continuous input range: 0.5 Arms/5 Arms/30 Arms
Functions with Digital Oscilloscopes, ScopeCorders and other waveform measuring instruments
Maximum power point tracking (MPPT) charge controllers play a crucial role in the optimization of renewable energy system efficiency and performance. Through dynamic tracking of a renewable energy source’s maximum power point, an MPPT controller enables more efficient energy harvesting, faster charging, and adaptability to changing environmental conditions.
Looking for a turnkey high-speed data transfer solution with better bandwidth and minimal manual overhead?
The 10Gb Ethernet option on the Yokogawa Test&Measurement DL950 ScopeCorder fits that very role and makes capturing and recording high-speed data seamless and convenient.
Record data at 50 times the speeds of traditional Ethernet and USB connections and automatically transfer data to your PC in a single step using the IS8000 Integrated Software Platform.
The multi-unit synchronization option for the Yokogawa Test&Measurement DL950 ScopeCorder lets you time synchronize up to five DL950 ScopeCorders, for up to 160 channels of voltage, current, temperature, strain measurements, and more. This video walks you through how to set up and connect the multiple DL950 ScopeCorders, take measurements, and pull the data from all of the instruments for analysis with the IS8000 Integrated Test and Measurement Software Platform.
Learn what signal types can be input into a scope using a Yokogawa Test&Measurement DL950 ScopeCorder, a unique combination of a 32-channel mixed signal oscilloscope and portable DAQ that captures both high-speed transient events and long-run trends.
We are going live on YouTube to answer your questions about the Yokogawa Test&Measurement DL950 ScopeCorder. Join us as we discuss how to make the most of this versatile instrument based on your application needs. Whether you’ve worked with a ScopeCorder for years or curious if it is a good fit for your engineering work group, this live stream can help.
Learn how to sync video data from a high-speed camera with data acquisition devices and scopes used by engineers in test and measurement applications.
Why should you be concerned with your product’s power system voltage and current harmonics? From an engineering perspective, harmonics produce excessive heat in equipment that causes significant damage and results in inefficient operation. From a business perspective, compliance is an absolute requirement for entry into global markets. To minimize or eliminate these issues and establish acceptable levels of harmonics, numerous power quality standards with specifications and limits for harmonic distortion, such as IEEE 519-2014 and IEC61000-3-2, have been introduced. During this webinar, attendees will gain knowledge on the inner workings of harmonics, learn best practices for accurately measuring harmonics, learn to recognize and distinguish the critical difference between DFT and FFT, and discover important measurement tradeoffs across various test equipment.
With ongoing innovations in motor and inverter technologies seeking to advance global decarbonization objectives in the automotive industry, it’s crucial that engineers have a thorough understanding of how to properly analyze these systems.
This complimentary webinar provides engineering professionals involved in motor and control system development with insights that enable data benchmarking and troubleshooting issues related to energy efficiency in electric vehicle (EV) powertrains.
Key webinar topics include: